Primary Air Systems – fans and associated equipment with FM/EN approved thermal mass flowmeters used to accurately and reliably monitor primary air flowrates essential in maintaining optimum combustion performance

Flame Scanners – use of state-of-the art FM/EN approved ultra-violet (UV) and infra-red (IR) systems sourced in North America or Europe

Burner Management Systems – provision of PLC-based systems for single and multi-fuel applications in compliance with North American, European or other specific standards

Ignitor Systems – natural or propane gas pilots for continuous or intermittent use, high-energy ignitors with automatic retraction system

COMBUSTION BY DESIGN

ANCILLARY EQUIPMENT

As part of system design, KFS offer a number of ancillary equipment items which enhance or complete the combustions system upgrade. Options are available for process and detailed design only, or full equipment supply:

Fuel Handing – valves trains for all gaseous and liquid fuels, and solid fuel storage and feed systems, all in accordance with customer and local specifications, and meeting appropriate regional standards.

KFS NCG lances – custom-designed to handle single or multiple streams (SOG, HVLC, LVHC, etc) to minimise impact on main burner and kiln operation while also resolving issues such as ring formation.